How to select model from characteristic chart

Centrifugal Type
  • Find the required flow rate (110L/min.) along the horizontal axis
  • Find the required total head (30m) along the vertical axis
  • Find the intersect point where the vertical line from flow rate and horizontal line from the total head
  • Find the curve that is immediately above this point
  • The model for this curve (15PHCNAS6) will be the suitable one for the requirement